Domain 1: Architectural Drawings (Construction Documents)

Question 1

A reduced-size plan print measures approximately 3 feet across a door leaf when checked against its printed scale. The written plan dimension and current door schedule both specify a 3-foot-6-inch leaf. Current elevations, frame details, and addenda agree; only the ruler measurement differs. What should the estimator enter in the takeoff?

Show answer & explanation

Correct answer: B - A 3-foot-6-inch leaf, using the coordinated written dimensions.

Domain 2: Specifications

Question 2

A hardware specification requires the contractor to test every installed electrified opening in its specified normal, fire-alarm, and power-loss states, record the results, and correct sequence failures before acceptance. Under CSI SectionFormat, where does this requirement belong?

Show answer & explanation

Correct answer: A - Part 3 - Execution: field quality control

Domain 3: Codes and Standards

Question 3

An 84-person Group A meeting room has a latched, 90-minute fire door. The project uses the 2021 IBC and NFPA 80 (2019), with no applicable panic-hardware exception. During scheduled hours, the owner wants push-pull passage without operating a lever or touchpad. Which arrangement can provide this convenience while restoring positive latching on a fire signal?

Show answer & explanation

Correct answer: B - Listed fire exit hardware with electric latch retraction that de-energizes on alarm, restoring latching.

Question 4

An inspection under the 2010 ADA Standards records four measurements for a non-fire-rated interior manual door: 33 inches of clear width with the leaf at 90 degrees; operating hardware 41 inches above the floor; 4.1 lbf to swing the unlatched leaf; and 3.6 seconds for the closer to move the leaf from 90 degrees to 12 degrees. The opening is 8 inches deep, the door latches reliably, and all other applicable requirements are satisfied. What belongs on the punch list?

Show answer & explanation

Correct answer: C - Slow the closing sweep to at least 5 seconds and recheck reliable latching.

Domain 4: Detailing (Scheduling)

Question 5

A fire-rated pair is detailed with a rim fire exit device and closer on each leaf, striking a compatible listed removable mullion. There is no overlapping astragal, and the assembly instructions permit either leaf to close first. A reviewer adds a coordinator solely because the opening is a fire-rated pair. How should that addition be resolved?

Show answer & explanation

Correct answer: D - Delete the coordinator; this listed arrangement has no leaf-closing sequence to coordinate.

Domain 6: Hardware

Question 6

A classroom's approved egress design permits a lever-operated lock. Staff must be able to lock or unlock the corridor lever with a key from inside, without opening the door. The corridor-side key must also control that lever, and the inside lever must always permit immediate egress. Which lock function fits?

Show answer & explanation

Correct answer: D - Classroom security

Question 7

A delivery cart has pushed an office door far enough for its lever to strike adjacent glazing. The closer's backcheck is adjusted within the manufacturer's limits, and hold-open operation is not required. Which change provides a defined limit to opening travel rather than relying on hydraulic resistance?

Show answer & explanation

Correct answer: A - Install a compatible, properly anchored positive stop.

Domain 7: Doors and Frames

Question 8

An interview-room opening requires a complete assembly rated at least STC 45. Acceptance is based on laboratory evidence for the furnished configuration; field testing is not specified. Proposal X documents STC 46 for its exact leaf, frame, glazing, seals, threshold, and hardware. Proposal Y advertises an STC 50 leaf but substitutes perimeter and bottom seals not covered by its test evidence. Both proposals meet the remaining requirements. Which conclusion is supported?

Show answer & explanation

Correct answer: B - X substantiates the assembly requirement; Y does not substantiate its proposed seal configuration.

Domain 9: Keying

Question 9

Facilities wants one staff-entrance cylinder to accept existing change keys from two separate departmental master-key groups, outside the entrance cylinder's ordinary hierarchy. The departmental cylinders must remain keyed different. The key-system designer warns that this arrangement can consume capacity and create unintended key interchange. What request is being evaluated?

Show answer & explanation

Correct answer: C - Cross-keying the common entrance

Domain 10: Electrified Hardware

Question 10

An electric latch-retraction device requires at least 22.0 VDC at its terminals during pull-in. It draws 1.20 A during pull-in and 0.25 A while holding. The supply maintains 24.0 VDC at its output during either state. The two-conductor cable run is 180 feet one way, and each conductor has a resistance of 0.0060 ohm per foot. Ignore contact resistance. Which assessment correctly evaluates the cable during pull-in?

Show answer & explanation

Correct answer: C - 21.41 V reaches the device; a lower-resistance cable run is needed.